Testing

Continuity of CPC
Inspection & Testing
IET Student’s Guide – Testing the continuity of circuit protective conductors (CPC)
This video was produced by the IET to guide apprentices through the correct procedures involved in testing the continuity of circuit protective conductors (CPC). Testing the continuity of the circuit protective conductor (CPC) is absolutely essential to confirm that your installation meets the requirements of the Wiring Regulations as well as to complete exams in accordance with the requirements of awarding bodies.   View all of the IET’s Student’s guide…
protective-bonding-conductor
Inspection & Testing
Measuring the continuity of the protective bonding conductor
In this video, Gary Hayers from Tresham College explains how you would go about measuring the continuity (resistance in Ohms) of the protective bonding conductor to water and gas. The video was made as a students training aid for testing continuity of the protective bonding conductor. This is the conductor that connects to the intake point consumers side of the metal gas pipe, metal water pipe and metal oil pipe in an electrical…
Checking-continuity-of-ring-final-circuit
Inspection & Testing
Checking continuity of a ring final circuit with unintentional spurs
This diagram provides guidance for checking the continuity and polarity of ring final circuit conductors with unintentional spurs for compliance with Regulation 612.2.2. This should be viewed as a continuation of the post: Checking continuity of a ring final circuit with no spur. Ensure installation, or appropriate part of it, is securely isolated, and proved to be so, before proceeding. Measurement to be taken at each and every socket outlet. Measured values…
Checking-continuity-of-ring-final-circuit
Inspection & Testing
Checking continuity of a ring final circuit with no spur
This diagram provides guidance for checking the continuity and polarity of ring final circuit conductors with no spur for compliance with Regulation 612.2.2. This should be viewed as a continuation of the post: Checking the continuity of a ring final circuit. Ensure installation, or appropriate part of it, is securely isolated, and proved to be so, before proceeding. Cross-connect the incoming phase with the outgoing circuit protective conductor (CPC) of the circuit and…
Checking-continuity-of-ring-final-circuit
Inspection & Testing
Checking continuity of a ring final circuit
This diagram provides guidance for checking the continuity of ring final circuit conductors for compliance with Regulation 612.2.2. This should be viewed as step two to the post: Checking the continuity of live and protective conductors. Ensure installation, or appropriate part of it, is securely isolated, and proved to be so, before proceeding. Cross-connect the incoming neutral conductor with the outgoing phase of the circuit, and vice versa. Measure the resistance phase…